Any idea what may be causing this? Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Can I spray the timer while there is electricity going in the timer box? "logo": {
Reset the clock on the timer to the correct time to get it back to the desired on/off times. Any advice on how to fix. The 12 Best Pool Timers of 2022 - WildRiver There are many reasons why your pool timer may not be working. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. This is hard to check if you are not qualified. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. You can turn off Freeze protection and it should stop, or replace the probe if faulty. Or be loose and not making good contact. No broken or loose wires visible. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. View more property details, sales history and Zestimate data on Zillow. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. To do this, pull the yellow-faced time dial (clockface) toward you. If not, the motor may be failing. I have the Intermatic T103 autotimer on my pool. Hello, newer pool guy here. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. by pool co. , so wondered about the cost. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Black goes to _1 I have an intermatic timer thats 2 years young. That will do it. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Then turn the breaker, that the time clock is connected to, off and back on again. It should loosen up after a few goes when the grease and gunt dissolve. "@type": "ImageObject",
"width": "611",
Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Was a good island when all the day trippers left - Review of South Sea Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. Any other thoughts? This div height required for enabling the sticky sidebar. I flicked the switch between on and off and it will not shut off. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. I replaced the pump and still nothing is moving. Pop-in a new timer mechanism, and replace the wires to the previous configuration. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. See the point above if it is. Your email address will not be published. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. I also dont see any ants or other insects. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. For Sale: 2 beds, 2 baths 1152 sq. If you look closely (with a flashlight and your glasses! A wire inside the motor may be touching another wire, or the metal sides of the motor. on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. If you loosen the hold down screw to much it could separate from the timer pin. How Does My Pool Timer Work? | eHow I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Intermatic Pool Timer, tips & troubleshooting Reset the clock to the correct time. Timer must be reset for current time after power outage. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Ive seen it happen from lightning strikes, or insect infestation. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. LIMITED TO A ONE-TIME RUN OF 666 UNITS. Start with the easy checks. I need to replace a timer for my pool vacuum. When I put the new one on, the trippers do not work. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. It should be 110V or 220V AC. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. I have to reset the time every day. "author": {
If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. As it get cooler you can cut it down to 5 or 6 hr a day . No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Wont work manually or by timer function. Basically 12 real life hours equals about 14 on the timer. Wont power on pump but can hear timer clicking away. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. },
Hi Mike, yes I sent you an email to your yahoo acct. I looked to see if the gears on the timer are running. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. I had the exact same thing happen recently. Why it always stop around 10pm by itself and not moving again? Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Does the tripper work on other areas of the clock, like near the off tripper? The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. NEW CONSTRUCTION. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. Below is a breakdown of how to wire different Intermatic timer models. Found the answer. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Intermatic t101 timer troubleshooting - Ask Me Help Desk Sometimes its way quick just to replace it rather than spend hours troubleshooting. Give it a little squirt of WD-40 or similar lubricant. (usually not). Until it came in, I manually turned on and the tripper turned it off. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. It sounds like the Line and Load wires are reversed. Take them off and inspect them. Flip it from where it is now, to the opposite side. we purchased the house 5 years ago so not sure how old the timer is? If you use our referring links, it costs you nothing extra. 220V clocks have 5 terminals, 110V clocks have 3 terminals. If the pump doesnt come on, follow the steps below. However, after several hours, maybe overnight, the associated breaker will trip. Why do we stock so many pool parts? Learn more about pool care and repair. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Intermatic T100 Series 40 Amp 24-Hour Outdoor Mechanical Timer with The other gears are not and the pump will not turn on or off unless done manually. Clean the gears with a toothbrush if you see debris or gunk in them. Hi Davey, I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Any suggestions as to how to test clock feed? Basically youre eliminating possibilities until you find the cause. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Save my name, email, and website in this browser for the next time I comment. "publisher": {
The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. do i need to do something different? My intermatic timer is about two years old as well. I not sure if this is the best timer to use. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. You dont have two OFF trippers, right? Sometimes during power surges or lightning, these will be fused together and not come apart. You will first want to look at the pool timer and see if you have two timer pins. The trippers push on a tab on the on/off switch. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. HI Jeff, do you have power outages sometimes? Was a good island when all the day trippers left I went to the control panel and saw that the timer needle stopped just after the start pointer. Hi Jere, that could be the timer motor failing. You can replace it but its really just easier to replace the entire mechanism. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. The timer quit after a nearby lightning strike. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. "@type": "BlogPosting",
Date Listed: 18/02/2023; . This morning the customer said it wasn't turning off. I believe its the manual on/off switch that is the problem. It is an ON tripper right? The problem lies, where the power dies, as they say, Thanks for the response. },
So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. View community ranking In the Top 5% of largest communities on Reddit. Wired correctly, #10 wire, nothing. But my new timer will not work either. Electrical Monke Aug 25, 2021 #22 It's broken. That should quiet it down. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. It was always fine before. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Required fields are marked *. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Thanks again for your help. Ideally, the switch would be placed after the timeclock, not before. Hello have a question some what related. Second thing to check is the dial bent or warped, in that area where the on tripper is? Hi, then the power for the clock must be from the switch, and not from the breaker? Are the trippers slid all the way onto the dial fully? Just some ideas. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. how do I check the manual over ride switch to see if it is off? Watch these tips and tricks before replacing it. Hi, Davy, seeing lots of complaints here. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool The most common pool timer used for inground pool pumps is the Intermatic time clock. Perhaps you had a power outage during the night? Almost like it doesnt have the strength to click the timer on or off. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am.
Shane Johnston Death, Articles P
Reset the clock on the timer to the correct time to get it back to the desired on/off times. Any advice on how to fix. The 12 Best Pool Timers of 2022 - WildRiver There are many reasons why your pool timer may not be working. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. This is hard to check if you are not qualified. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. You can turn off Freeze protection and it should stop, or replace the probe if faulty. Or be loose and not making good contact. No broken or loose wires visible. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. View more property details, sales history and Zestimate data on Zillow. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. To do this, pull the yellow-faced time dial (clockface) toward you. If not, the motor may be failing. I have the Intermatic T103 autotimer on my pool. Hello, newer pool guy here. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. by pool co. , so wondered about the cost. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Black goes to _1 I have an intermatic timer thats 2 years young. That will do it. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Then turn the breaker, that the time clock is connected to, off and back on again. It should loosen up after a few goes when the grease and gunt dissolve. "@type": "ImageObject",
"width": "611",
Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Was a good island when all the day trippers left - Review of South Sea Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. Any other thoughts? This div height required for enabling the sticky sidebar. I flicked the switch between on and off and it will not shut off. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. I replaced the pump and still nothing is moving. Pop-in a new timer mechanism, and replace the wires to the previous configuration. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. See the point above if it is. Your email address will not be published. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. I also dont see any ants or other insects. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. For Sale: 2 beds, 2 baths 1152 sq. If you look closely (with a flashlight and your glasses! A wire inside the motor may be touching another wire, or the metal sides of the motor. on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. If you loosen the hold down screw to much it could separate from the timer pin. How Does My Pool Timer Work? | eHow I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Intermatic Pool Timer, tips & troubleshooting Reset the clock to the correct time. Timer must be reset for current time after power outage. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Ive seen it happen from lightning strikes, or insect infestation. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. LIMITED TO A ONE-TIME RUN OF 666 UNITS. Start with the easy checks. I need to replace a timer for my pool vacuum. When I put the new one on, the trippers do not work. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. It should be 110V or 220V AC. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. I have to reset the time every day. "author": {
If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. As it get cooler you can cut it down to 5 or 6 hr a day . No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Wont work manually or by timer function. Basically 12 real life hours equals about 14 on the timer. Wont power on pump but can hear timer clicking away. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. },
Hi Mike, yes I sent you an email to your yahoo acct. I looked to see if the gears on the timer are running. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. I had the exact same thing happen recently. Why it always stop around 10pm by itself and not moving again? Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Does the tripper work on other areas of the clock, like near the off tripper? The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. NEW CONSTRUCTION. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. Below is a breakdown of how to wire different Intermatic timer models. Found the answer. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Intermatic t101 timer troubleshooting - Ask Me Help Desk Sometimes its way quick just to replace it rather than spend hours troubleshooting. Give it a little squirt of WD-40 or similar lubricant. (usually not). Until it came in, I manually turned on and the tripper turned it off. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. It sounds like the Line and Load wires are reversed. Take them off and inspect them. Flip it from where it is now, to the opposite side. we purchased the house 5 years ago so not sure how old the timer is? If you use our referring links, it costs you nothing extra. 220V clocks have 5 terminals, 110V clocks have 3 terminals. If the pump doesnt come on, follow the steps below. However, after several hours, maybe overnight, the associated breaker will trip. Why do we stock so many pool parts? Learn more about pool care and repair. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Intermatic T100 Series 40 Amp 24-Hour Outdoor Mechanical Timer with The other gears are not and the pump will not turn on or off unless done manually. Clean the gears with a toothbrush if you see debris or gunk in them. Hi Davey, I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Any suggestions as to how to test clock feed? Basically youre eliminating possibilities until you find the cause. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Save my name, email, and website in this browser for the next time I comment. "publisher": {
The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. do i need to do something different? My intermatic timer is about two years old as well. I not sure if this is the best timer to use. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. You dont have two OFF trippers, right? Sometimes during power surges or lightning, these will be fused together and not come apart. You will first want to look at the pool timer and see if you have two timer pins. The trippers push on a tab on the on/off switch. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. HI Jeff, do you have power outages sometimes? Was a good island when all the day trippers left I went to the control panel and saw that the timer needle stopped just after the start pointer. Hi Jere, that could be the timer motor failing. You can replace it but its really just easier to replace the entire mechanism. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. The timer quit after a nearby lightning strike. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. "@type": "BlogPosting",
Date Listed: 18/02/2023; . This morning the customer said it wasn't turning off. I believe its the manual on/off switch that is the problem. It is an ON tripper right? The problem lies, where the power dies, as they say, Thanks for the response. },
So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. View community ranking In the Top 5% of largest communities on Reddit. Wired correctly, #10 wire, nothing. But my new timer will not work either. Electrical Monke Aug 25, 2021 #22 It's broken. That should quiet it down. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. It was always fine before. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Required fields are marked *. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Thanks again for your help. Ideally, the switch would be placed after the timeclock, not before. Hello have a question some what related. Second thing to check is the dial bent or warped, in that area where the on tripper is? Hi, then the power for the clock must be from the switch, and not from the breaker? Are the trippers slid all the way onto the dial fully? Just some ideas. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. how do I check the manual over ride switch to see if it is off? Watch these tips and tricks before replacing it. Hi, Davy, seeing lots of complaints here. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool The most common pool timer used for inground pool pumps is the Intermatic time clock. Perhaps you had a power outage during the night? Almost like it doesnt have the strength to click the timer on or off. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am.
Shane Johnston Death, Articles P